Point-of-care ultrasound compression of the carotid artery for pulse determination in cardiopulmonary resuscitation

Background:

-shorter (and accurate) pulse/rhythm checks are better
-manual pulse checks are often not reliable and frequently exceed the recommended 10s window
-cardiac POCUS has been used as a possible adjunct but there have been concerns about interruptions in compressions 
 
Study:
-Single center, prospective, 25 patients with OHCA (155 pulse checks total)
-some exclusions: early cessation of CPR (49), "manpower shortage" (35)
-two physicians concurrently performing manual palpation (MP) of femoral artery and POCUS-carotid artery compression (POCUS-CAC) during pulse checks
-each with stopwatch to measure time to pulse judgment
-prev training with hour lecture and hands-on demonstration on how to assess/interpret the compressibility and pulsatility of the carotid artery
 
POCUS-CAC: 
-linear probe placed transversely across patient’s middle neck to identify the carotid artery and internal jugular vein on the screen
-probe pressure was applied until the internal jugular vein was completely compressed
-absent pulse = lack of pulsation and complete compression of the carotid artery under probe pressure
-present pulse = any visual pulsation or incomplete compression of the carotid artery
 
Results:
-the average time for carotid pulse identification per patient significantly different
      -POCUS-CAC was 1.62 (1.14– 2.14) s 
      -MP 3.50 (2.99–4.99) s
-in all 155 pulse checks, the time to complete a pulse check with POCUS-CAC never exceeded 10 s, whereas five cases with MP exceeded this.
 
Takeaways/caveats:
-larger study is needed and focus should be on rhythm checks, but if staffing allows, can consider utilizing POCUS-CAC as an adjunct for pulse checks 
-the MP time in this study is much shorter than in prev studies
-would be interesting to see if the findings would be even more exaggerated in a larger patient population (average BMI in the study was 23!)
-small sample, did not address carotid stenosis/atherosclerosis, no standardization for intensity of compression applied

 

References

S. Y. Kang, I. J. Jo, G. Lee et al., Point-of-care ultrasound compression of the carotid artery for pulse determination in cardiopulmonary resuscitation, Resuscitation, https://doi.org/10.1016/j.resuscitation.2022.06.025